Event Id’s
eventID : 7001
VSS
VssAdmin: Unable to create a shadow copy: The shadow copy provider had an error. Please see the system and application event logs for more information.
Command-line: ‘C:\WINDOWS\system32\vssadmin.exe Create Shadow /AutoRetry=5 /For=\\?\Volume{c5b975b9-d6bc-11da-90ad-0050569c1bf5}\’.
eventid 12317,
File Server Resource Manager failed to enumerate share paths or DFS paths. Mappings from local file paths to share and DFS paths may be incomplete or temporarily unavailable. FSRM will retry the operation at a later time.
Event ID 12289, VSS
Volume Shadow Copy Service error: Unexpected error DeviceIoControl(\\?\Volume{c5b975b9-d6bc-11da-90ad-0050569c1bf5} – 0000012C,0x0053c008,000374C0,0,000384C8,4096,[0]). hr = 0x80070005.
For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp
Oplossing
Microsoft heeft een patch vrijgegeven welke een aantal shadow copies problemen oplost. Je kunt patch hier downloaden KB891957
Mocht deze patch het probleem niet verhelpen dan kun het als volgt oplossen: Restore de shadow copies configuratie naar default, dus disabled. Let op! alle shadow copies gaan verloren als je dit doet!
Configureer nu shadow copies zoals het was voordat je het naar default had gezet.
Mogelijke Oorzaak
Mijn collega ICT-Freak Jimmy kreeg deze event id’s nadat hij de partities van zijn fileserver had vergroot.